INFORMATION RELEASE AB 185/1

SPECIALIX I/O 8+ or MCA DTC
and NCR UNIX SVR4 03.02.
This Admin Bulletin replaces AB185 completely.
Remove the existing AB185, and replace with this
AB185/1
SPECIALIX I/O 8+
- A reported problem has occurred on systems running Unix SVR4 03.02., where ports
connected to the Specialix I/O 8+ may hang, because of continuous logins echoing between
the VDU and the Port.
- To overcome the problem two things need to be done:-
* at the end of the tty label clocal needs to be inserted.(see para 6)
* on the Port Service, CONNECT ON CARRIER needs to be set to OFF.
DTC
- Problems have been reported on systems running Unix SVR4 03.02., where printers
connected to the DTC give a unix error of Auto-retrying. The printers either wont
start, or stop during a print.
- If a system exhibits this problem carry out the following action:-
* at the end of the tty label clocal needs to be inserted (see para 6)
clocal Insertion
- To insert the clocal, after the cread in root
Enter vi /etc/ttydefs
use /19200 or the up and down keys to access the relevant line
use the left and right arrows to position the cursor after cread
Enter i for insert and then type in clocal ESC
Save and exit by entering : <CR> wq! <CR>
- Repeat para 5 as necessary
- See the example on page 2 of ttylabel printouts