Dell PowerVault 220S and 221S Systems User's Guide
Drives | |
SCSI hard drives | support for up to fourteen 1-inch-by-3.5-inch LVD Ultra 160 and Ultra3 SCSI hot-plug hard drives, at speeds of 10K or 15K rpm and capacities of 18 GB or 36 GB (73 GB for 10K rpm drives) |
SCSI | |
Buses | can be configured for a single 14-device SCSI bus, a single clustered 13-device SCSI bus, or two independent 7-device SCSI buses |
Back-Panel Connectors | |
SCSI connector | 68-pin shielded P-type SCSI for connection to host |
Backplane Board Connectors | |
Hard drives | fourteen 80-pin SCA-2 connectors |
Power supply/cooling module | 2 high-current connectors |
Enclosure management modules (EMM) | 210-pin connector |
Split-bus module | 180-pin connector |
Enclosure Modules | |
EMM | 2 warm-pluggable modules |
Split-bus module | 1 warm-pluggable module with an external slide switch to change between split-bus, joined-bus, and cluster modes |
SCSI terminator card | 1 warm-pluggable module to the terminate SCSI bus in nonredundant EMM configurations |
LED Indicators | |
Front panel | 5 LED status indicators for power, fault, split bus, cluster mode, and over-temperature |
Hard-drive carrier | 1 single-color activity LED and 1 two-color LED status indicator per drive |
EMM | 3 LED status indicators for power, fault, and active status |
Split-bus module | 1 LED indicator for power |
Power supply and cooling module | 3 LED status indicators for power supply status, power supply fault, and AC status and 2 for cooling module fault |
Power Supplies | |
Wattage | 600 W |
Heat dissipation | 200 W |
Voltage | 100240 V rated (actual 85264 V) |
Frequency | 5060 Hz |
Amperage | 9.4 A at 100 V, 4.6 A at 200 V |
Physical | |
Height | 13.26 cm (5.22 inches) |
Width | 44.58 cm (17.55 inches) |
Depth | 50.8 cm (20 inches) |
Weight PowerVault 220S PowerVault 221S |
32.4 kg (71.5 lb.) maximum redundant configuration with all hard drives installed 42.2 kg (93.0 lb.) maximum redundant configuration with all hard drives installed |
Environmental | |
Temperature: Operating Storage |
10° to 35°C (50° to 95°F) 40° to 65°C (40° to 149°F) |
Relative humidity Operating Storage |
8% to 80% (noncondensing) 8% to 95% (noncondensing) |
Altitude Operating |
16 to 3048 m (50 to 10,000 ft) |
BTU per hour | 2750 |