SVR4 # 1
![]() |
FECO: | SVR4 # 1 |
MODIFICATION NO: | N/A | |
PRODUCT: | UNIX SVR4 03.02 on NCRS20 | |
SUB-ASSEMBLY: | N/A | |
ESTIMATED MAN HOURS | N/A | |
CLASS OF CHANGE: | MANDATORY | |
REASON FOR CHANGE: | ISSUE OF INSTALLATION INSTRUCTIONS FOR UNIX SVR4 03.02 ON NCRS20. |
1. INTRODUCTION.
Due to changes in the architecture of an NCR S20 the load sequence for SVR4 MP-RAS is slightly different. The following procedure should be followed when loading or rebuilding an S20.
NOTE.
The S20 can ONLY be installed from CD-ROM, tape and boot flex installations are not supported and will not work correctly.
The oldest release of operating system that will support the S20 is 03.02.00.11.
Currently the MP-RAS core CD version is 03.02.00.08 and the maintenance CD version is 03.02.00.11.
2. BIOS CONFIGURATION.
The following settings need to be changed in the BIOS to support MP-RAS.
BIOS Option | Required Setting |
Primary and Secondary IDE Master and Slave | None |
Memory Cache | Enabled |
Large Disk Access Mode | Other |
On Board PS/2 Mouse (IRQ 12) | Enabled |
PCI-IRQs to IO-APIC Mapping | Disabled |
3. IRQ SETTINGS.
The following IRQs should to used where necessary.
IRQ |
Used By |
0 |
System resources |
1 |
System resources |
3 |
Serial port 2 |
4 |
Serial port 1 |
5 |
Spare |
6 |
Floppy controller |
7 |
Parallel port |
9 |
Spare |
10 |
Internal ethernet adapter |
11 |
AIC-7880 SCSI controllers |
12 |
Mouse controller |
13 |
System resources |
14 |
Mylex RAID array adapter |
15 |
Spare |
Interrupts 5 and 9 are usually made available for use by Specialix I/O8+ and RIO adapters.
4. SYSTEM DUMP CONFIGURATION.
PCI slot 4 (the slot closest to the CPUs) must only be occupied by an additional SCSI controller. If any other adapter is installed in this slot it will create an interrupt conflict that will cause the machine to hang when a system dump occurs.
The slot can also be left empty.
5. INSTALLATION.
NOTE.
The machine MUST be booted from the Maintenance Updates CD-ROM for the installation to work correctly.