MODIFICATION No: N/A
PRODUCT: DATA LOGIC DL60 BAR CODE READER
SUB-ASSEMBLY N/A
ESTIMATED MAN HOURS N/A
CLASS OF CHANGE: INFORMATIONAL
REASON FOR CHANGE TO RELEASE THE EDP STANDARD SETTINGS

1. Introduction

        This feco is to release the EDP standard settings for the data logic Dl60 bar code reader. This BCR is
        normally connected to a cashwide till by a 9pin d type connector and is called on mec -

        Cash-BCR.

2. Change

        The default setting of the BCR is 9600, 8, n. Cr+lf.

        The EDP setting is 9600, 8, 1, n, cr.

        To set up the bcr you require the operators manual containing bar codes to be used in the set up.

3. Connect the BCR to a cashwise till and power on.

        (tech serv ref: 17/10/1)

4. Set up

        Action page no scan

4.1. To enter configuration mode 6.8 $+

4.2. To default settings 6.9 default code

4.3 note: paragraph 4.2 above takes the bcr out of configuration mode back into read mode .

4.4. To re-enter configuraion mode 6.8 $+

4.5. To remove the lf from the defaulted setting :-

        Note all the asc11 characters below are zero's.

        6.47ea11

        Appendix abc section 7 page 3 asc11 characters

        Od

        6.47 ea12

        Appendix abc section 7 page 3 00

        6.47 ea13

        Appendix abc section 7 page 3 00

        6.47 ea14

        Appendix abc section 7 page 3 00

4.6. To exit and save changes 6.46 $-

5. Testing

        Scan sample bar codes and check that the correct characters are displayed on the end.

6. Recording action

        No specific recording action

        Normal documentation.