FECO WYSE # 9/1
![]() |
FECO: | WYSE # 9/1 |
MODIFICATION No: | N/A | |
PRODUCT: | WYSE 55-ES | |
SUB-ASSEMBLY | N/A | |
ESTIMATED MAN HOURS | N/A | |
CLASS OF CHANGE: | INFORMATIONAL | |
REASON FOR CHANGE: | TO LIST THE SETUPS FOR A SERIAL SLAVE PRINTER ON THE AUX PORT |
1. Change
This is additional information to Feco WYSE #9 and is a new page 4 of 4.
2. MEC description
Insert the new page 4 after the existing page 3.
(tech serv ref 22/11/3)
8. Additional settings for using a serial printer on the aux port.
8.1 system port = 9600,7,1,space,xi0
8.2 serial printer setting for the wyse-55-es as follows:-
F1
F2 genrl
COLUMNS - 80PERSONALITY -VPTA2
LINES -24SCRL -JUMP
PAGE -1 X LINESRCV CR -CR
CURSOR -BLINK BLKENHANCE -ON
DISPLAY -DARKAUTOSCRL -ON
AUTOPAGE -OFFMONITOR -OFF
SCRN SAVER -ONSTATUS LINE -ON
CHAR CELL -10 X 15WRAP EOL -ON
80 X 132 CLR -ONRECOGNISE DEL -OFF
F3 KEYBOARD
F4 COMM
KEYCLICK -OFFCOMM -FDX
KEYLOCK -CAPSMDM RX HSK -XON
LANGUAGE -USAUX RX HSK -NONE
REPEAT -ONXMT LIM -NONE
CORNER KEY -FUNCTMDM RC HSK LEVEL -128
KEY CODE -ASCIISEND ACK -OFF
ANSWERBACK MODE -OFF
MDM XMT HSK -NONE
AUX XMT HSK -XON
F5 PORTS
F6 MISC
MDM BAUD RATE -9600WPRT INTENSITY -DIM
AUX BAUD RATE -9600BLK END -US/CR
HOST PORT -MODEM PORTMARGIN BELL -OFF
MDM DATA/PARITY -7,SWPRT REV -OFF
AUX DATA/PARITY -7,SATTRIBUTE -PAGE
PRINTER -SERIALBELL VOLUME -1
MDM STOP BITS -1WPRT UNDRLN -OFF
AUX STOP BITS -1MULTIPLE PAGE - OFF
NULLS SUPPRESS -OFFREST/ACT TIMES -NONE
F7 AND F8 SETTINGS AS STANDARD