FECO 3000 # 59
![]() |
FECO: | 3000 # 59 |
MODIFICATION No: | N/A | |
PRODUCT: | NCR3438 - S40 | |
SUB-ASSEMBLY | N/A | |
ESTIMATED MAN HOURS | N/A | |
CLASS OF CHANGE: | INFORMATIONAL | |
REASON FOR CHANGE: | DISPLAY OF ERRONEOUS ERROR. |
1.Explanation
The following erroneous error will be displayed when running the
diagnostic disk
(Intel 3.17 diags) on a S40 containing an isa digiboard at i/o address
100:
------------------------------------------------------------
Com2.interrupt
Error com2.interrupt
Timeout error!
A transmit holding reg. Empty interrupt was not generated on com port 0x2f8
Standard error code 00808101
Com2.interrupt failed
-------------------------------------------------------------
2.Solution:
To eliminate this error message, change the ISA DIGIBOARD address to 110.
Or ignore the error if it is not applicable to the fault you are testing for.
3.Recording action
Complete all documentation.
(tech serv ref 97/15
CSSB 96-0045)