FECO WYSE # 10

FECO: WYSE # 10
MODIFICATION No: N/A
PRODUCT: WYSE MC5C
SUB-ASSEMBLY N/A
ESTIMATED MAN HOURS N/A
CLASS OF CHANGE: INFORMATIONAL
REASON FOR CHANGE: TO LIST THE STANDARD EDP SETTINGS OF THE WYSE MC5C VDU

1.     Reason for change

This is to list the standard EDP settings for the WYSE mc5c VDU which is also known as a visa mc25 or a link mc3+. They all look identical. The mono VDU has a main and parallel port. They also have customised firmware and BML badging.

2.      Change

The spec is shown on page 2. The front and rear views are shown below.

(tech serv ref 96/01)

3.      Specification

4.      mec identification

The units are known as :-

Mc5c(white)

Mc5c(green)

Mc5c(amber)

5.     servicing

Normal warranty and servicing procedures apply. Initially servicing will be by replacement.

6.     Configuration

6.1   to enter set up mode press shift + select use the f keys to select the required group of parameter. Use !
        And ! To move within parameters block. Use - and - to select parameters option. The general set up screen
        is shown below.

1. Header block

2. Parameter item block

3. Option selection block

4. Function key directory

5. Host port indicator block

6.2   press d to return all parameters to original factory settings.

Press r to restore most recently saved settings.

Press s to save present settings.

Press f9 to exit set up mode.

6.3   set parameters to the required settings and save. Edp standard settings shown in para 7.

7.     EDP standard settings

F1 GEN

Emulationaddsvpauto page off

Enhancementsonwarning bell on

Virtualterminaloffmargin bell off

Scroll stylejumpbell sound 1

Auto scrollonblock terminator us/cr

Auto wraponsend ack on

Receivedcrcrmonitor mode off

F2 COMM

Main baud9600auxl baud 9600

Main data/parity8/noneauxl date/parity 8/none

Mainstop bits1auxl stop bits 1

Mainrcvhndsknoneauxl rcv hndsk none

Mainxmthndsknoneauxl xmt hndsk none

Commodefull duplexprinter parallel

Disconnect2 secclear communication on/off

F3 DISP

Columns80attributes char

80/132 clearoffwprtintensity normal

Lines24wprtreverse on

Pages1 x lineswprtunderline off

Status lineonrefresher rate 60hz

Cursor styleblink blockpoundchar british

Cursoronauto font load on

Screen saver15 minspage edit off

Backgrounddark

F4 KBD

Key clickoffxmt limit none

Key repeatonf key xmt limit none

Key lockcapskey code asc11

Return keycrlanguage uk

Enter keycrdecimal separator point

Backspace keydel/bsepc panse key pause

Left alt keyfunctprint key remote

Break

F5 ANSI

Fkey lockoffprint multinational

Feature lockoffsend all

Key padnumericsend area screen

Xfor termeosprint area screen

Cursor keysnormalsend term none

Char modemultinationalprint term none

Keystypewriterprint mode normal

VT100 I dvt100auto answer back off

Press s to save.

F9 TO EXIT.

MEC listed987