FECO WYSE # 7
![]() |
FECO: | WYSE # 7 |
MODIFICATION No: | N/A | |
PRODUCT: | WYSE 55 | |
SUB-ASSEMBLY | N/A | |
ESTIMATED MAN HOURS | N/A | |
CLASS OF CHANGE: | INFORMATIONAL | |
REASON FOR CHANGE: | TO LIST THE SETTINGS FOR THE WYSE 55 WHEN USED ON THE MOLECULAR SYSTEM |
Change
1. This Feco is to be used in conjunction with FECO WYSE # 6/1.
2. When the WYSE 55 is used on a molecular system utilising the
leicester operating system (los), it requires
different set ups to those listed on page 2 of
feco WYSE # 6/1.
3. The revised settings are shown over the page.
(tech serv ref 22/11/1)
Set up the VDU as follows:
F1 DISP F2 GENRL
COLUMNS -80PERSONALITY -WYSE 50
LINES -24SCRL -JUMP
PAGE -1 X LINESRCV CR -CR
CURSOR -BLINK BLKENHANCE -ON
DISPLAY -DARKAUTOSCRL -ON
AUTOPAGE -OFFMONITOR -OFF
SCM SAVER -ONSTATUS LINE -ON
SHAR CELL -10 X 15WRAP EOL -ON
80 X 132 CLR -OFFRECOGNISE DEL -OFF
F3 KEYBD F4 COMM
KEYCLICK -OFFCOMM -FDX
KEYLOCK -CAPSMDM RC HSK -NONE
LANGUAGE -UKAUX RC HSK -NONE
REPEAT -ONXMT LIM -NONE
MARGIN BELL -OFFMDM RC HSK LEVEL -192
CORNER KEY -FUNCTSEND ACK -ON
KEY CODE -ASCIIANSWERBACK MODE -OFF
BELL VOLUME -1MDM XMT HSK -NONE
AUX SMT HSK -NONE
F5 PORTS F6 MISC
MDM BAUD RATE -9600WPRT INTENSITY -NORMAL
AUX BAUD RATE -9600BLK END -US/CR
HOST PORT -MODEM PORTPRINTER ATTACHED -OFF
MDM DATA/PARITY -7/EVENWPRT REV -ON
AUX DATA/PARITY -7/EVENATTRIBUTE -PAGE
MDM STOP BITS -1NULLS SUPPRESS -OFF
AUX STOP BITS -1WPRT UNDRELN -OFF
MULTIPLE PAGE -OFF
REST/ACT TIMES -NONE
F7 ANSI F8 ANSI 2
CHAR SET -NULTINATIONALPRINT -ASCII
CURSOR KEYS -NORMALSEND -ALL
FEATURE LOCK -OFFXFER TERM -EOS
CHAR MODE -MULTINATIONALPRINT AREA -PAGE
KEYPAD -NUMERICSEND AREA -PAGE
FKEY LOCK -OFFAUTO ANSWERBACK -OFF
ANSI ID -VT 100PRINT TERM -NONE
DEL -DEL/CANSEND TERM -NONE
NEWLINE -OFFKEYS -TYPEWRITER
RETURN = YES
DELETE = NO