FECO COMMS # 38
![]() |
FECO: | COMMS 38/1 |
MODIFICATION No: | N/A | |
PRODUCT: | CRAY DCX 818 MULTIPLEXOR | |
SUB-ASSEMBLY | N/A | |
ESTIMATED MAN HOURS | N/A | |
CLASS OF CHANGE: | INFORMATIONAL | |
REASON FOR CHANGE: | TO LIST THE REVISED SETTINGS |
Introduction
1. cray multiplexors have changed their name to case. In future they may be referred to as either cray or case.
2. there is a need to raise the standard settings for use on the cray dcx818 mult plexor.
3. on the existing FECO COMMS #38
* delete para 6 but not the supervisor menu diagram.
* delete para 7.4.
4. Insert new attached sheet, headed `page 2a of 14' and `page 3a of 14' between the
existing pages 2 & 3. The
new para 6 and para 7.4 are on this sheet.
5. on the existing FECO COMMS # 38:- amend paragraph 8.3
Setting f number of channels
Change "set 4 or 8" to "set to 5 or 9".
(tech serv ref 97\13)
New para 6.
6. configuration supervisor.
6.1 manufacturers default is for any port to be used for supervisor access; and the
access is achieved by
entering
setting can cause problems.
6.2.1 the edp standard will be to restrict supervisor access to the first channel,
channel 1; and to bar supervisor
access through all the other channels.
6.2.2 the supervisor entry by the user escape character, is changed to break, break, break.
6.3 to enter the configuration/supervisor mode, connect a vdu to channel 1, set to the speed of that channel.
6.4 log on by entering the user escape character. Edp standard is break, break, break,
with at least a one second
gap between each key press.
For adds 4000 vdu's the edp standrd is:-
CTRL-BREAK, CTRL-BREAK, CTRL-BREAK
Note:- this will only be effective after it has been changed from the manufactures default of CTRL-A.
6.5 the initial screen is displayed with instructions.
6.6 note: entering
6.7 at `enter password prompt', enter: logon.
6.8 at `local remote manager prompt" enter l, r, m1 or m2 as required.
The supervisor menu is displayed on page 2.
Note: m1 and m2 are to be used to access the
supervisor at remote ends when there are 3 nodes
connected together.
6.9 to exit from the supervisor menu select x, the unit responds `goodbye'
New para 7.4
7.4 select option 1 to configure all parameters or letter to configure only one, then
reset parameters as necessary
to those bellow:-
Host end both ends peripheral end
A line speed9600
B local echooff
C character code8 + 1
D uso connect characteroff
E system messagesoff
F paritytrans
G term.flow control x-onoffdc1
H term.flow control x-offoffdc3
I flyback bufferingoff
J buff.overflow prot x-ondc1dc1
K buff.overflow prot x-offdc3dc3
L cts to follow rtson
M special flow controlnone
N user escape character
(channel 1 only)bkbkbk
User escape character
(all other channels)off
O inactivity timeroff
P parity error character*
Q host abr (for dll)off
R host control monitoroff
S setup pins
T data limit48