FECO MT # 86

FECO: MT # 86
MODIFICATION No: N/A
PRODUCT: MT 645
SUB-ASSEMBLY N/A
ESTIMATED MAN HOURS N/A
CLASS OF CHANGE: UPON FAULT OCCURRING
REASON FOR CHANGE: INTERMITTENT FAILURES, RESETS, RANDOM SELF TESTING, RANDOM NVRAM FAULTS, POOR PAPER STACKING.

* THIS FECO SHOULD BE READ IN ADDITION TO FECO MT # 65 *

Change

Use a meter to check the following points:

    1.  ensure modification in FECO MT # 65 has been implemented.

    2.  check the following resistances. They should be less than 5 ohms measured from the metal work of the
         mains input panel to:

A)the frame of the printer.

B)the paper tray

C)the interface plate

D)paper exit plates

E)metal paper guides

F)system

If the readings are high then corrective action must be taken by use of additional ground wires or scraping paint away to allow metal to metal contact.

(tech serv ref 24/3/1)

    3.  refer to FECO MT # 77 to identify shuttle drive motor type. If type fitted has diodes in its leads check
         these are grounded.

Testing

Functionally test printer.

Recording action

Record in customer site log.

Return to Index