FECO COMMS # 39/1
![]() |
FECO: | COMMS # 39/1 |
MODIFICATION No: | N/A | |
PRODUCT: | CRAY DCX 832 MULTIPLEXOR | |
SUB-ASSEMBLY | N/A | |
ESTIMATED MAN HOURS | N/A | |
CLASS OF CHANGE: | INFORMATIONAL | |
REASON FOR CHANGE: | TO LIST THE REVISED SETTINGS FOR THE CRAY DCX 832 MULTIPLEXOR |
Introduction
1. Cray multiplexors have changed their name to case.
In future they may be referred to as either cray or case.
2. There is a need to revise the standard settings for use on the cray/case dcx 832.
3. On the existing FECO COMMS #39:-
* delete para 6. But not figure 4.3
* delete para 7.4
4. insert new attached sheet between existing page 2 and page 3.
New sheet is titled "page 2a of 14" and "page 3a of 14" and contains revised para 6 and revised para 7.4.
5. para 9.3. Addition of parameter.
Setting e: number of channels
Add:- "9, 17, 25, or 33."
(tech serv ref 97/12)
New para 6.
6. configuration supervisor.
6.1 manufacturers default is for any port to be used for supervisor access; and the
access is achieved by
entering
setting can cause problems.
6.2.1 the EDP standard will be to restrict supervisor access to the first channel, i.e.
channel 1; and to bar
supervisor access through all the other
channels.
6.2.2 the supervisor entry by the user escape character, is changed to break, break, break.
6.3 to enter the configuration/supervisor mode, connect a VDU to channel 1, set to the speed of that channel.
6.4 log on by entering the user escape character. The EDP standard is:- break, break,
break, with at least a one
second gap between each key press.
For adds 4000 VDU's the EDP standard is:-
CTRL-BREAK, CTRL-BREAK, CTRL-BREAK
Note:- this will only be effective after it has been changed from the manufacturers default of ctrl-a.
6.5 the initial screen is displayed with instructions.
6.6 note:- entering
6.7 at `enter password prompt', enter: logon.
6.8 at `local remote manager prompt' enter l, r, m1 or m2 as required.
The supervisor menu is displayed.
Note:- m1 and m2 are to be used to access
the supervisor at remote ends when there are 3 nodes
connected together.
6.9 from the supervisor menu the required option can be selected.
6.10 to exit the supervisor menu select x, the unit responds `goodbye'.
New para 7.4
7.4 select option 1 to configure all parameters, or letter to configure only one, then
reset parameters as
necessary to those below:-
Host endperipheral end
A line speed9600
B local echooff
C character code8 + 1
D uso connect characteroff
E system messagesoff
F paritytrans
G term.flow control x-onoffdc1
H term.flow control x-offoffdc3
I flyback bufferingoff
J buff. Overflow prot x-ondc1dc1
K buff. Overflow prot x-offdc3dc3
L cts to follow rtson
M special flow controlnone
N user escape character
(channel 1 only)bkbkbk
User escape character
(all other channels)off
O inactivity timeroff
P parity error character*
Q host abr (for dll)off
R host control monitoroff
S setup pins
T data limit48